State of charge and health of aged cells, in minutes instead of hours
A battery only provides current and voltage; the state of charge has to be estimated by a model. As a cell ages, capacity, voltage curve and internal resistance change, and a model built for new cells becomes wrong. Our method measures the state of health in a short check-up and adjusts the estimator accordingly.
Why ageing breaks the estimate
Three things change as a cell ages:
- Usable capacity dropsIn our test data to between 51 % and 100 % of the new value.
- The open-circuit voltage curve shiftsBy about ±10 mV, which corresponds to 1 to 1.5 percentage points of state of charge.
- Internal resistance risesBy up to 70 % from new to aged, which distorts the voltage the estimator sees.
An overestimated state of charge leads to premature shutdown, an underestimated one to overcharging. Existing remedies need either the cycling history of the cell, a full discharge test, or heavy machine-learning models that do not run on small microcontrollers.
Two time scales: check-up and tracking
1. Check-up
- A short block of current pulses is applied at any state of charge, with no prior full charge
- The voltage response shows how far the cell has aged
- A compact model turns this into the state of health
- Capacity, voltage curve and cell model are then set to match the aged cell
- No online learning, so the estimate stays stable
- Optional: impedance measurement instead of pulses, slightly more accurate but needs extra equipment
2. Tracking
- A lightweight filter combines measured current and voltage into a stable state of charge
- A few dozen bytes per cell, no stored history
- About 80 arithmetic operations per step, no floating-point unit required
- Runs on the entry-level microcontroller already in the BMS, no extra hardware
- 16 cells use less than 1 % of such a microcontroller
Validated on 228 commercial cells
Public ageing dataset of 228 lithium-ion cells (NMC/C-SiO) aged for over a year under 76 conditions. 136 cells for training, 46 for validation, 46 unseen cells for testing.
| Capacity source | Duration | Mean SoC error |
|---|---|---|
| Factory value, never recalibrated | – | 4.7 pp |
| Pulse check-up (Ethast) | 3.5 min | 2.1 pp |
| Full capacity test | 5 – 48 h | 1.7 pp |
Mean absolute error in percentage points over 46 unseen cells, each filter starting 5 points too low. Paired difference to the factory value −2.6 pp, 95 % confidence interval [−3.3; −1.9].
Low computing requirements, no extra hardware
| Requirement | Ethast | Published alternatives |
|---|---|---|
| Memory per cell | 40 B | 180 B – 4.4 kB |
| Operations per estimate | ≈ 80 | up to 13 000 |
| Memory for a 100-cell pack | ≈ 4.4 kB | 18 – 440 kB |
| Hardware | entry-level microcontroller | larger controller or external processor |
Measured on an entry-level 32-bit microcontroller without floating-point unit, 16-cell application, worst case over 12 723 steps.
The advantage grows with the number of cells. The estimator fits next to the existing BMS firmware, so no additional controller, memory or processor is needed, and the bill of materials does not change.