Battery test equipment
From the formation of single cells to the end-of-line test of complete packs. Our team of experienced engineers designs the systems, and we take care of specification, documentation, commissioning and service.

Test stand for traction and storage batteries
Bidirectional test stand for battery packs from electric and hybrid vehicles, two-wheelers, fuel cells and supercapacitors. Discharge energy is fed back into the grid. Drive cycles can be imported from spreadsheets.
Test types
- Cycle life, capacity, DC internal resistance per cell
- Charge and discharge characteristics, charge retention, efficiency
- Over-charge and over-discharge tolerance, temperature characteristics
- Standard dynamic tests and simulated vehicle operation
| Grid connection | 3~ 400 V ±15 %, 50 Hz |
|---|---|
| Output voltage | up to 800 V DC |
| Output current | up to ±800 A |
| Power | up to 750 kW |
| Control / measurement accuracy | 0.1 % of full scale |
| Response time | ≤ 20 ms |
| Power factor / THD | > 0.95 / ≤ 8 % |
| Efficiency | > 90 %, feedback ≥ 90 % |
| Operating modes | CC, CV, CC-CV, CP, CR, ramp, pulse, rest, cycles (9 999 steps, 8 nesting levels) |
| Interfaces | CAN, Ethernet; links to BMS, MES, climate chamber; optional cell voltage and temperature acquisition |

End-of-line test system for battery packs
Automated acceptance test at the end of the line: barcode binding, automatic start, automatic pass/fail. Combines charge/discharge test, electrical safety, BMS function test and auxiliary functions in one station.
Test groups
- Charge/discharge: standard and real drive cycles, capacity, DC internal resistance, self-discharge, efficiency, cell voltage consistency, temperature behaviour, battery simulator mode
- BMS test: charging and vehicle communication, initialisation, insulation monitoring, accuracy of cell voltage, temperature, total voltage and current, SOC setting and SOC accuracy, protection functions, supply
- Electrical safety: insulation resistance, high-voltage withstand, leakage current
- Auxiliary functions: pre-charge circuit, leak tightness, open-circuit voltage, digital I/O, polarity, HV interlock, fans, service switch, cooling and heating, nameplate coding
| Version | Economy | Standard | High-end |
|---|---|---|---|
| Voltage / current accuracy | 0.5 % FS | 0.1 % FS | 0.5 % FS |
| Voltage ripple | ≤ 0.5 % | ≤ 0.5 % | ≤ 0.2 % |
| Current rise (battery load, no overshoot) | ≤ 100 ms | ≤ 10 ms | ≤ 5 ms |
| Charge/discharge switch-over | ≤ 200 ms | ≤ 20 ms | ≤ 10 ms |
| Recording interval | ≤ 500 ms | 100 ms | 5 ms |
Common: 3~ 400 V supply, power factor > 0.99, THD ≤ 5 %, efficiency > 92 %, ≤ 70 dB(A). Auxiliary channels 0–5 V / 0–20 V (0.1 % FS) and −40 to 150 °C (±0.5 °C). Emergency stop per channel, power-fail protection with resumption of the test sequence, DBC configuration for CAN.

Cell formation and capacity grading
Formation, capacity measurement and sorting of single cells for module and pack production and for laboratory life testing. Software for online and offline statistics, curve comparison and automatic grouping (matching).
| Voltage range | 0–5 V or 0–30 V, resolution 1 mV |
|---|---|
| Current ranges | 30 / 60 / 100 / 200 / 400 / 500 / 600 / 1 000 A per channel |
| Accuracy | ±(0.1 % FS + 0.1 % of reading), resolution 1 mA |
| Main channel sampling | ≥ 10 ms |
| Dynamics | 0 → full load ≤ 5 ms, charge ↔ discharge ≤ 10 ms |
| Temperature (option) | 3 channels per test channel, −40 to 150 °C, ±1 °C |
| Grid feedback (option) | ≥ 75 % |
| Protection | power-fail resumption, over/under-voltage, over/under-current, capacity, temperature, voltage trend, reverse polarity, short circuit, open circuit |
| Interfaces | CAN, Ethernet, RS485 |

Battery simulator
Programmable bidirectional IGBT source/sink that reproduces the current–voltage behaviour of battery packs including internal resistance, SOC, charge and discharge characteristics. For testing chargers and charging stations, drivetrains, motor controllers, storage inverters and UPS systems.
| Output voltage | 20–1 000 V DC |
|---|---|
| Topology | four-quadrant SPWM rectifier and high-frequency DC-DC converter, two stages |
| Power factor | > 0.99, low grid distortion |
| Output | modular units, single or in series/parallel; CV, CC, CP |
| Energy | feedback into the grid, integrated brake unit with automatic switching |
| Software | programmed test sequences, load profiles, data recording and curve analysis; remote control by third-party systems |

IGBT charge/discharge system with DC bus
Formation system for lead-acid and lithium cells: several charge/discharge units share a DC bus so that discharge energy flows directly into parallel charging circuits. Surplus is fed back by a regenerative unit; only residual energy is dissipated in resistors.
- Modes: charge, discharge, pulse (±), rest, cycles; CC, CV, CV with current limit, CC with voltage/time limit
- End conditions: time, voltage, current, charge quantity
- One host computer supervises up to 144 circuits; data recording, analysis, production reports
- Protection against over-current, over-voltage, phase loss, short circuit; seamless restart after power failure
| Voltage / current accuracy | ≤ 0.5 % FS |
|---|---|
| Timing accuracy | ≤ 10 s / 24 h |
| Setting range | voltage 10–100 %, current 1–100 % |
| Power factor / THD | ≥ 0.95 / ≤ 10 % |
| System efficiency | ≥ 90 % |
| Pulse shape | rectangular, minimum width 1 s |
| Cell monitoring | 18 measuring points per circuit, interval ≥ 5 s, ±0.2 % FS (12 V) |

Cycle life tester
Laboratory instrument for capacity, charge acceptance, charge retention, discharge behaviour, cycle life and over-charge/deep-discharge tolerance of lead-acid and industrial batteries. Modular electronic load with 32-bit DSP, 16-bit multi-channel ADC and Ethernet networking of several instruments.
- Charge CC/CV, pulse charge (±), discharge CC, CP, CR, cycles, rest
- Switch conditions: time, voltage, current, capacity, energy, power, resistance, dI/dt, dU/dt; optional cell voltage, temperature, internal resistance
- Interfaces: 3× RS485, 2× CAN, Ethernet; Modbus, Modbus TCP, CANopen on request
| Series | Voltage | Current per circuit | Circuits | Batteries |
|---|---|---|---|---|
| 18 V | 4.5–18 V | 10 / 20 / 30 / 50 / 100 A | 6 | 6 V, 12 V |
| 18 V | 4.5–18 V | 200 A | 3 | 6 V, 12 V |
| 72 V | 4.5–72 V | 10 / 20 / 30 / 50 A | 6 | up to 60 V |
| 72 V | 4.5–72 V | 100 A / 200 A | 3 / 2 | up to 60 V |
Accuracy ≤ 0.5 % FS, current rise ≤ 50 ms, 1–9 999 cycles, timing ≤ 10 s / 24 h, recording from 1 s. Cabinet 780 × 780 × 2 000 mm.

High-current discharge tester
High-current discharge test (cold cranking current) for 6 V and 12 V batteries. Modular high-power electronic load with fast, overshoot-free current rise; networking and central control via Ethernet.
| Discharge currents | 500 / 1 000 / 1 500 / 2 000 / 3 000 / 4 000 A |
|---|---|
| Voltage range | 4.5–18 V |
| Accuracy | ≤ 0.5 % FS |
| Current rise | ≤ 25 ms |
| Modes | CV, CC, CP, CR, rest, cycles; switching by time, current, voltage |
| Dimensions | 780 × 780 × 2 000 mm |

Cell voltage and temperature monitor
Acquisition of voltage, temperature, time and optionally current and internal resistance of all cells during formation and testing; basis for capacity grouping. Works with our systems, stand-alone or with third-party equipment.
| Voltage channels | 24 per module, 0–5 V (also 0–12 V, 0–100 V), 0.1 % FS, 1 mV |
|---|---|
| Temperature channels | 24 per module, −40 to 150 °C, ±0.5 °C (option ±1 °C) |
| Recording | interval ≥ 5 s |
| Interfaces | RS485, CAN, Ethernet |
| Number of modules | any, configured per system |
Production and formation software
Supervisory system for formation and testing in client–server architecture: graphic overview of the formation area, detail window per circuit, recipe editor with up to 500 steps, prioritised alarms, history and reports.
- Direct control of all charge/discharge circuits: charge, discharge, rest, cycles
- Recipes with CC, CV, ramps and user-defined profiles; step end by cycles, current, voltage, Ah, temperature or time
- Calculation and history database, periodic and on-demand analysis
- Capacity grouping by end voltage, end time, Ah or power
- Connection to MES/ERP via database or file interfaces
Automated test lines and fuel cell test systems
Complete end-of-line test lines with automatic handling, barcode binding and MES link, and test systems for fuel cell engines and stacks. Engineered per project.



Production and test halls equipped by our team



Delivery and service in Europe
Every system is delivered with documentation in English or German, review of CE-relevant documents and on-site commissioning. Spare parts and remote maintenance are organised from Munich. Recipes and reports are adapted to your plant standards.
Tell us cell format, voltage and current range, channel count and planned throughput. You will receive a configuration with data sheet within a few days.